華東動力40余年,
累積點滴,改進改善,
堅持專業(yè)專心配套。
提供全系列發(fā)電機組電力配套解決方案,
緊隨合作伙伴向前的每一時刻!
誠信厚道,華東動力自始至終!
受結構制約,柴油發(fā)電機組無法做到完全防水,當雨季/臺風季來臨時,柴油發(fā)電機組便有可能遭受洪水、暴雨等自然災害的影響,當柴油發(fā)電機組內(nèi)部進水時,用戶要及時采取必要的措施,斷開外電源及蓄電池接駁線,不可運轉發(fā)動機,也不可嘗試盤轉曲軸,禁止運轉發(fā)動機,同時檢查各個部位的進水情況。
Due to structural constraints, diesel generators can’t be completely waterproof.When the rainy season season comes, generator may be affected by natural disasters such as floods and rainstorms. When water enters the generator,you should take necessary measures to disconnect the external power supply and the battery connection line,prohibit running the engine, and check the water ingress of each part.
進水常見問題
1、檢查排氣管路(排煙管最低處或消聲器)的排水構件是否有水排出。
Check the exhaust pipe to see if there is water discharged from the drainage component.
2、檢查空氣濾清器外殼是否有積水,濾芯是否被水浸漬。
Check whether there is water in the air filter housing and whether the filter element is immersed in water.
3、檢查發(fā)電機外殼底部是否有積水。
Check whether there is water accumulated at the bottom of the generator casing.
4、檢查散熱器、風扇、聯(lián)軸器等回轉部件是否堵塞。
Check radiator, fan, coupling for blockage.
5、外部是否有機油、燃油或水的滲漏。
Whether there is leakage of organic oil, fuel or water from the outside.
6、拆下?lián)u臂室蓋,觀察是否有進水。檢查發(fā)電機繞組絕緣/污染情況。
Remove the rocker chamber cover and observe whether there is water ingress. Check the insulation and ontamination of the generator windings.
7、檢測控制線路和輸出電路的絕緣。檢測控制面板模塊、各儀表、告警裝置、啟動開關。
Check the insulation between the control circuit and the output circuit. Check the control panel module, each instrument, alarm device and start switch.
注意:絕對不能讓水侵入發(fā)動機的燃燒室!
Note: Never let water enter the combustion chamber of the engine!
進水處理方法
柴油發(fā)電機組進水后的處理辦法:
Treatment after water enter the generator:
當判斷柴油發(fā)電機組發(fā)動機的燃燒室沒有進水,絕緣符合要求時,可啟動柴油發(fā)電機組。在啟動時要注意以下問題:
When confirm there is no water in the combustion chamber and the insulation meets the requirements,can start the generator. Pay attention to the following issues when starting:
1、在啟動前進行所有檢查,包括排放燃油箱積水。電氣系統(tǒng)逐步上電,觀察是否有異常。
Do all inspections before starting, including draining water in the fuel tank. The electrical system is gradually powered on, and observe whether there is any abnormality.
2、連續(xù)啟動發(fā)動機的時間不得超過30秒鐘。若發(fā)動機不能著火,則檢查燃油管路及電氣回路,一兩分鐘后再次啟動。
Start the engine continuously shall not exceed 30 seconds. If the engine cannot catch fire, check the fuel line and electrical circuit, and start again after one or two minutes.
3、檢查發(fā)動機聲音是否有異常,是否有異味。檢查電氣儀表的顯示、液晶顯示屏是否斷屏或者顯示不清。
Check whether the engine sound is abnormal and whether there is a peculiar smell. Check whether the display of the electrical instrument and the LCD screen are broken or unclear.
4、密切觀察機油壓力和水溫度,如果油壓或溫度不符合技術規(guī)范,應關閉發(fā)動機。停機后,檢查一次機油平面。
Closely observe the oil pressure and water temperature. If the oil pressure or temperature does not meet the technical specifications, the engine should be shut down. After stopping, check the oil level.
當判斷發(fā)動機可能進水、發(fā)電機絕緣不符合要求時,切勿擅自維修,應尋求發(fā)電機組廠家的專業(yè)技術人員的幫助。
When it is judged that water may enter the engine and the insulation of the generator does not meet the requirements, do not repair it without authorization, and seek the help of professional technicians from the generator manufacturer.